Maintenance windows

Daily windows when a host is expected to go down, such as a nightly reboot or backup, so nobody is woken for it. Problems still there when the window closes alert as usual.

1 min read

A host that reboots every night at 04:00 shouldn't page anyone at 04:00. A maintenance window holds its alerts while it's expected to be down.

Add windows under Configure › Alerts: a name, the hosts, a daily start time, a time zone and how long it lasts.

What a window does

While a window is open, for the hosts it names:

  • problems don't open or fire incidents,
  • incidents already open stay as they are: no repeats, and no "resolved" while the host reboots.

When it closes, everything is judged as usual, so a host that's still down then alerts.

Only conditions that belong to a host are held. Checks of sites, mail and DNS aren't: a website down is down, whoever's rebooting. A window may name a cluster, which holds everything about that cluster.

Use the host's own time zone, so daylight saving moves the window with the host's timer.

In the config file

Writing maintenance in obs-beacond.yaml, even as maintenance: [], makes the file the place for windows:

maintenance:
  - name: nightly reboot
    hosts: [web1, web2, db1]
    daily: "04:00"
    timezone: Europe/Berlin       # default UTC
    duration: 20m